ELASTO-MAT™ D&G (DAMP AND GREEN) - NEW!
|
  
|
Single component, rapid curing, fluid applied waterproofing membrane for damp and green concrete.
For Full Documentation On This Item See Our General Product Index
|
Available Colors:
|
A self-priming, rapid moisture-curing, VOC compliant, modified polyurethane waterproofing membrane that can be applied to Green or Damp Concrete just a few days old. ELASTO-MAT™ D&G is commonly used between slabs on plaza decks, parking decks, roof terraces, podiums, and reflecting pools. It is also used for waterproofing foundation walls, landscaped areas, planter boxes, tunnels, etc. ELASTO-MAT™ D&G is an effective membrane for use on concrete, wood, metal and other masonry surfaces. In some cases, a primer may be required. Available in three viscosities:
- SL (Self-Leveling) grade: Suitable for horizontal applications.
- V (Vertical) grade: Suitable for horizontal and vertical applications.
- SL GRADE: Is solvent free.
INSTALLATION:
Surfaces to be waterproofed must be clean and surface dry. Concrete slabs should have a light steel trowel followed by a fine hair broom or equivalent finish and should be water cured. Consult Architect or Engineer for minimum cure time on concrete before water cure can be stopped and foot traffic is permitted. Allow a minimum of 24 hours for concrete surface to dry after stopping water cure on decks or removing forms from walls. If release agents are present, they must be removed before the application of ELASTO-MAT™ D&G. Following good drainage practice, the structural slab should be sloped to drain a minimum of 1/8" (3.2mm) per running foot (30.5cm). All shrinkage cracks shall be treated with a 60 mil (1.5mm) coating of ELASTO-MAT™ D&G, six inches (15.3cm) wide centered over the crack. Moving structural cracks greater than 1/16" (1.6mm) can be routed out and caulked with Grade T, striped with bond breaker tape and coated with a 60 mil (1.5mm) detail coat of Membrane, or treated with fabric embedded in membrane, centered over the crack. Consult your local Pacific Polymers technical representative for further information.
LIMITATIONS:
- Do not apply to contaminated surfaces.
- Not to be used as an exposed or wearing surface.
- Use with adequate ventilation.
- Concrete forms must be removed for a minimum of 24 hours before ELASTO-MAT™ D&G can be applied.
- Do not use curing compounds.
- Bond Breakers and Form Releases must be removed.
|
|
|
|